Product description:
Self-operated
electric temperature control valve (for larger caliber and thermal oil
control), the valve features only the most common 220V power supply, the
use of the media itself is adjusted to the energy directly to the
steam, hot water, hot oil and gas and other media The temperature of the
implementation of automatic regulation and control, can also be used to
prevent overheating or heat exchange occasions, the valve structure is
simple, easy to operate, the selection of a wide range of temperature
control, fast response time, reliable sealing performance, and can be
adjusted during operation , Which is widely used in chemical, petroleum,
food, textile, hotels and restaurants and other departments of hot
water supply.
Part Information:
◆ Structure and Principle
Control
valve consists of main valve, intelligent actuator and sensor composed
of three parts, according to user needs, respectively, heating and
cooling of two structures.
1. The structure and principle of the heating control valve, see the attached diagram:
Before work, the main valve core is in the half-open position and the sensor is in a natural state. Connect the power, the main spool fully open. The medium flows into the main valve body in the direction of the arrow, and the heat storage tank is heated by the valve core. When
the temperature rises to the corresponding set value, the sensor
generates a corresponding linear signal input integrated intelligent
actuator, then drive the stem, the valve spool displacement, turn off
the main valve to stop heating. When the
temperature is lower than the set value, the sensor generates a linear
signal input to the actuator, which drives the valve element to be
involute, allowing the medium to flow into the thermal storage tank
according to the parabolic characteristic and heating up to the set
value. This controlled media is always in the set temperature range is controlled, so as to achieve the purpose of temperature control.
Outline drawing
(1) Intelligent actuator
(2) Main valve body
(3) Sensor
(4) Capillary tube
(5) Manual mechanism
Remarks: It is often said that the heating type, cooling type. In this valve as long as the spool structure can be replaced.
Technical Parameters:
◆ The main parameters and materials
1, the main parameters table
Nominal diameter (mm) | 15 | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | |
Nominal pressure PN (MPa) | 1.6 4.0 | ||||||||||||
Flow capacity (m 3 / h) | 5 | 7 | 10 | 16 | 25 | 40 | 63 | 100 | 160 | 250 | 400 | 630 | |
Rated travel (mm) | 6 | 8 | 10 | 14 | 20 | 30 | 30 | 40 | |||||
Temperature adjustment range (℃) | 0 to 120: 100 to 250 | ||||||||||||
Adjustment accuracy (℃) | ± 1 ~ ± 5 | ||||||||||||
Use media | Steam, water, oil, gas | ||||||||||||
allow Leakage | Hard seal | 10 -4 X valve rated capacity | |||||||||||
Soft seal | "0" | ||||||||||||
Capillary length | 3m, 5m, 10m | ||||||||||||
Warm package into the depth | 270, 430, 630 | ||||||||||||
Coupling thread | 3/4 "1" |
◆ supporting the use of electric actuators related technical parameters
Nominal diameter DN (mm) | 20 | 25 | 32 | 40 | 50 | 65 | 80 | 100 | 125 | 150 | 200 | |
Electric actuator model | normal type | ZAZ-60 DKZ-310 | ZAZ-60 DKZ-310 | DKZ-410 | DKZ-410 DKZ-510 | |||||||
Electronic type | JHZAZ1 | JHZAZ2 | JHZAZ3 | JHZAZ3 | ||||||||
Electric Actuator Thrust (N) | normal type | 400 4000 | 400 4000 | 6400 | 6400 16000 | |||||||
Electronic type | 2000 | 4000 | 6000 | 8000 | ||||||||
The whole trip time (S) | normal type | 12.5 | 20 | 32 | 48 | |||||||
Electronic type | 30 | 30 | 48 | 60 | ||||||||
Power consumption (W) | normal type | 28 | 35 | |||||||||
Electronic type | 6 | 15 | 25 | 40 |
* The table data is only conventional configuration, the specific selection based on the main parameters and user requirements.
Connection standard:
◆ connection size and standard
· Flange standard: Cast iron flange according to GB4216-84, Cast steel flange according to GB9113-88
· Flange sealing surface type: PN10, PN16 convex PN40, PN64 concave surface, the valve body is concave
· Structure length: GB12221-89 Jacket
Insulation Jacket Heating Body Interface: Butt Weld φ18 × 4
* The body flange and flange end face distance can be manufactured according to user-specified standards. Such as ANSI, JIS, DIN and other standards.
◆ Ordering Information When
ordering, please provide the following information:
· Control valve name and model
· Nominal diameter (mm)
· Nominal pressure (MPa)
· Rated flow coefficient (Kv)
· Fixed flow characteristics
· Media name, valve pressure, temperature , Flow rate, etc.
· The whole machine mode of operation (electric open, electric) and the input signal
· Body, valve trim and packing material
· Accessories (manipulators, servo amplifiers, etc.)
· Other special requirements